mirror of
https://github.com/ClickHouse/ClickHouse.git
synced 2024-11-27 01:51:59 +00:00
e37e8f83bb
I saw the following in the logs for the failed test: 2023.05.16 07:12:12.894051 [ 262 ] {74575ac0-b296-4fdc-bc8e-3476a305e6ea} <Warning> ConnectionPoolWithFailover: Connection failed at try №1, reason: Timeout exceeded while reading from socket (socket (172.16.3.2:9000), receive timeout 2000 ms) And I think that the culprit is the test_distributed_replica_max_ignored_errors for which it is normal, however not for others, and this should not affect other tests. So fix this by calling SYSTEM RELOAD CONFIG, which should reset error count. CI: https://s3.amazonaws.com/clickhouse-test-reports/49380/5abc1a1c68ee204c9024493be1d19835cf5630f7/integration_tests__release__[3_4].html Signed-off-by: Azat Khuzhin <a.khuzhin@semrush.com> |
||
---|---|---|
.. | ||
configs | ||
__init__.py | ||
test.py |